Multifunction instrument for testing single-phase and three-phase photovoltaic systems and analysing mains quality in compliance with standard EN50160 |
 |
|
SOLAR300N allows carrying out all tests required for the verification of the efficiency of single-phase and three-phase photovoltaic systems. Testing photovoltaic systems requires contemporarily measuring environmental parameters (incident irradiation of modules, temperature of environment and modules) and electric parameters (continuous power, alternating power, etc.). Typically, modules and inverter can be positioned even at several tens of meters of distance, thus forcing the operator to carry out measurements in different places far from each other at the same time. To carry out these operations, connections by means of long cables or (wireless) radio connections could be necessary, but both these solutions are not acceptable. Cables could hamper the operator’s movements or be a hindrance, while radio waves would be attenuated by floors, reinforced concrete or metal structures, thus making communication impossible. In order to avoid the above-mentioned problems and to carry out measurements with the necessary contemporaneity, SOLAR300N is provided with a remote unit SOLAR-02, synchronized with the main unit. The remote unit is positioned next to the photovoltaic modules and it is connected to the probes for measuring environmental parameters (irradiation by reference cell HT304 and temperature). SOLAR300N is connected upstream and downstream of the inverter in order to acquire the electric parameters (continuous power and alternating power). The synchronization between the two units guarantees the necessary contemporaneity of measurements, the two separate and independent units make measurements comfortable and safe. SOLAR300N is also a powerful instrument for the complete analysis of mains quality in compliance with standard EN50160 (harmonic analysis, analysis of voltage anomalies, Flicker, unbalance, etc.). The management software TopView also provides the possibility of creating professional reports, which can be customized by adding the company’s logo, the customer’s data, comments, etc.
SOLAR300N demostration video
|
 |
| Download pdf |
|
|
STANDARD
CE mark
EN 61326 EMC Standards
EN 50160
EN 61010-032
EN 61010-1
FUNCTION
- DC/AC TRMS (single-phase and three-phase) voltage measurement
DC/AC TRMS (single-phase and three-phase) current measurement DC/AC (single-phase and three-phase) power measurement AC (single-phase and three-phase) energy measurement Measurement of power factor (cosphi) single-phase and three-phase Measurement of solar irradiation [W/m2] Measurement of environmental and module temperature by means of probe PT1000 Recording of voltage and current harmonics up to the 49th Recording of voltage anomalies (dips, peaks) Flicker analysis in compliance with standard EN50160 Recording of starting currents with a resolution of 10ms Recording of voltage fast transients (spikes) with a resolution of 5us Complete analysis of mains quality in compliance with standard EN50160 Numerical and graphical display of each quantity Recalling results on the display TFT colour display with touch screen Power supply with rechargeable Li-ION battery Memory extension by means of compact flash (CF card) Data transfer to external USB memory (memory stick) USB port for PC connection - Help on line at display
ACCESSORIES
Included accessories:
- SOLAR-02: Remote unit to record irradiation and temperature
- KIT800: Kit including 5 banana cables (black/blue/red/green/brown) + 5 alligator clips (black/blue/red/green/brown)
- HT4005K: Transducer for AC currents 0÷200 A AC, 3pcs
- HT4004N: Transducer for DC currents 0÷10 - 0÷100 A
- HT304: reference cell for irradiation measurement
- PT300N: Double temperature probe (PT1000 + environmental)
- A0055: Power supply 230V / 50-60Hz EU plug
- YABAT0003HT1: Li-Ion 3,7V rechargeable battery
- PT400: Touch screen pen
- TOPVIEW2007: Software on CD-ROM and USB connection cable C2007
- VA300: Carrying case
- User manual on CD-ROM
- Quick guide
- Calibration certificate ISO9000
Optional accessories:
- MPP300: Multi-string three-phase adaptor
- HT4004P: Unbatterried transducer for DC current 0-10, 0-100A, max diameter 30mm (**)
- HT96U: Transducer for AC currents (including leakage current) 0÷1 - 0÷100 - 0÷1000A
-
HT97U: Transducer for AC currents 0÷10 - 0÷100 - 0÷1000 A AC -
HT98U: Transducer for AC/DC currents 0÷1000 A AC/DC -
HP30C2: Transducer for AC currents 0÷200 - 0÷2000 A AC -
HP30C3: Transducer for AC currents 0÷3000 A AC -
HTFLEX33D: Flexible transducer for 3000A AC current, diameter 174mm (*) HTFLEX35: Flexible transducer for 3000A AC currents diameter 274mm (*) -
HT903: Transducer 3x1-5A/1V for connection to CTs with accessories -
SP-0400: Free hands kit 606-IECN: Connector with magnetic clip - (*) only for using the instrument as power quality analyser
- (**) to be used with MPP300 only
|
 |
 |
|
 |